WLK series program-controlled stable current power supply is a switch-type stable current power supply, which is mainly used to provide the exciting current of magnetic powder brake, magnetic powder clutch, eddy current brake; it has RS232 (or custom RS485) serial interface, and can communicate with computer and PLC controller.
I. Working method
WLK series program-controlled power supply has the following 3 working modes:
1. "way of communication. The RS232 (or custom RS485) port receives data instructions from the computer and outputs current.
2. "Remote" mode. It is controlled by external 0 ~ 10V (or customized 0 ~ 5V) signal and output current.
3. "Manual" mode. Controlled by "manual adjustment" potentiometer, output current.
When the WLK series program-controlled steady-current power supply and the PLC controller form a control system, it is recommended to use the "communication" method, which can eliminate the PLC.
D / A module.
Technical indicators
1. Input voltage: 220V ± 20% 50Hz
2. Output current: 0-1A (1A output type); 0-3A (3A output type); 0-5A (5A output type)
3. Output voltage: 0-40V (1A output type); 0-40V (3A output type); 0-80V (5A output type)
4. Stability accuracy: less than 1%
5. Response time: 0.1s
6. Insulation resistance: 220V Input and output terminals:> 10MΩ
7. Ambient temperature: below 50 ° C
8. Air humidity: <85% (25 ° C)
Panel configuration

"RS232 / 485" terminal description:
RS232 interface: 2 feet: TXD 3 feet: RXD 5 feet: ground
RS485 interface: 2 feet: A 3 feet: B 5 feet: ground
"Remote control" signal input:
Pin 1: Remote control signal (0-10V) input positive terminal;
2 feet: remote control signal (0-10V) input negative terminal;
"Output" side:
Main power output
Fourth, computer communication rules (PL0 mode)
The instrument adopts RS232 / RS485 data communication interface, and provides WLK3B.dll dynamic link library for users to call directly.
The WLK3B.dll dynamic link library includes the get_current procedure and the put_current function. The get_current procedure is used to read the current value, and the put_current function is used to output the current value.
DELPHI language procedures and functions are declared as follows:
function put_current (port, addr_mcu: integer; out_current: real): integer; stdcall;
procedure get_current (port, addr_mcu: integer; var in_current: real); stdcall;
The VB language procedures and functions are declared as follows:
Private Declare Sub get_current Lib "WLK3B.dll" (ByVal Port As Integer, ByVal addr_mcu As Integer,
in_current As Double)
Private Declare Function put_current Lib "WLK3B.dll" (ByVal Port As Integer, ByVal addr_mcu As
Integer, ByVal out_current As Double) As Integer
among them:
port: computer COM port value, its value is 1, 2, 3, etc .;
addr_mcu: the communication address of the power supply, its value is 9;
out_current: the current value output to the power supply (such as: 1.25 2.33, etc.);
in_current: The current value read from the power supply (eg: 1.25 2.33, etc.).
Out_current function return value description:
1. When the value is -1, the communication fails. Possible reasons are: the computer COM port value (port) is set incorrectly; addr_mcu
Wrong value
2. When the value is -2, it indicates that an error occurred during data transmission, and the power supply does not receive the command.
3. When the value is 1, the communication is correct.
Description of the return value of the in_current parameter during get_current:
1. When the value is -1, the communication fails. Possible reasons are: the computer COM port value (port) is set incorrectly; addr_mcu
Wrong value
2. When the value is -2, it indicates that an error occurred during data transmission. This communication data can be discarded.
3. When the value is -3, it means that the data from the power supply overflows and the communication data can be discarded.
4. When the value is greater than or equal to 0, the communication is correct, and the value is the collected current value.
V. PLC controller communication rules In order to simplify the PLC controller software programming, a simpler communication protocol is used, and the program-controlled power supply is half-work RS232 / RS485 receiving mode.
Program-controlled power supply has three data receiving methods.
PL1, PL2 mode:
1. Data format The frame data is 10 bits without parity bits, that is:
Start bit 8 data bits (lower first) Stop bit
2. Data transmitted
PL1 way:
The PLC sends 1 data to the program-controlled power supply, the range is 0-255, and the corresponding current is: 0 ~ range.
PL2 way:
The PLC sends two data to the program-controlled power supply. The two data are the same, the range is 0-255, and the corresponding current is: 0 ~ range; the program-controlled power supply determines whether the data is correct according to whether the two data received are the same. PL2 has higher reliability than PL1. The time interval (t) between the two data that the PLC sends to the program-controlled power supply continuously is about 1ms, which can be selected between 1ms <t <100ms.
PL3 way:
1. Data format The frame data is 11 bits, that is:
Start bit is 8 data bits (lowest first), 9th stop bit is 9th (parity bit), here is the address and data discrimination bits, 1 is address, 0 is data.
The instrument is only triggered by the address, that is, the host computer can only get the response of the instrument when it sends 09H to the program-controlled power supply (09H is the communication address of the program-controlled power supply) and the parity bit is 1. The 9th bit is the parity bit in the computer. The parity setting can change it.
2. The transmitted data host computer sends address 09H to the program-controlled power supply, and the 9th bit is 1; then it sends 1 data, the 9th bit is 0, and the range is 0-255.
The corresponding current is: 0 ~ range. The time interval (t) between two transmissions is about 1ms, and can be selected between 1ms <t <100ms.
Six, description
1. When the instrument is turned on, two frames of information are displayed, which are the factory number and the current range. If the programmed power supply is set to computer communication rules (PL0),
When the two frames of information are displayed, the indicators of the "communication key", "remote key" and "manual key" are all off; if it is the PL1 communication rule,
The “Communication Key” indicator is on; if it is a PL2 communication rule, the “Communication Key” and “Remote Key” indicators are on; if it is PL3
For communication rules, the indicators of "communication key", "remote key", and "manual key" are on.
2. Selection of communication rules and setting method of current range:
Press and hold the "Communication Key", turn on the power switch, the window displays "SEP" and enter the setting state; release, and then press the "Communication Key" again,
"PL0", "PL1", "PL2" or "PL3" characters are displayed, and you can use "Remote key" and "Manual key" to change to the desired value.
Press the "Communication Key" again to display the current range value. At this time, you can use the "Remote Key" and "Manual Key" to change to the desired value.
Turn off the power to complete the communication rules and range settings. For a steady current power supply, its range value is unique and cannot be changed at will.
The range value is set at the factory, and users are advised not to change it.
3. The user selects different control signals by pressing keys.
4. The ground terminal of the power plug must be reliably grounded.